Skip to content

Churchill

fullflow.Churchill

Churchill Darcy friction factor correlation.

Churchill computes a Darcy friction factor from mass flow, viscosity, hydraulic diameter, flow area, roughness, and Poiseuille number. The Churchill correlation provides a smooth transition across laminar, transitional, and turbulent Reynolds numbers.

Parameters

Name Type Description
namestr

Component name

networkNetwork

Network that owns this component

mass_flowState

Fluid mass flow rate. The absolute value is used

friction_factorState

Output Darcy friction factor

hydraulic_diameterState or float

Hydraulic diameter

dynamic_viscosityState

Fluid dynamic viscosity

cross_sectional_areaState or float

Flow cross-sectional area

roughnessState or float, optional

Absolute wall roughness

poiseuille_numberfloat, optional

Poiseuille number used for incompressible laminar flow

reynolds_numberState or float, optional

Output Reynolds number

Outputs

Name Type Description
friction_factorState

Darcy friction factor

reynolds_numberState or float, optional

Reynolds number