Miropolskii
Miropolskii film-boiling heat transfer coefficient for two-phase flow.
Miropolskii computes a convective heat transfer coefficient for film-boiling two-phase flow. It is useful for chilldown-style problems where vapor quality and separate liquid and vapor properties are available.
Parameters
| Name | Type | Description |
|---|---|---|
name | str | Component name |
network | Network | Network that owns this component |
mass_ | State | Fluid mass flow rate. The absolute value is used |
hydraulic_ | State or float | Hydraulic diameter of the flow passage |
cross_ | State or float | Flow cross-sectional area |
quality | State or float | Vapor quality |
vapor_ | State | Vapor density |
vapor_ | State | Vapor specific heat capacity |
vapor_ | State | Vapor dynamic viscosity |
vapor_ | State | Vapor thermal conductivity |
liquid_ | State | Liquid density |
reynolds_ | State or float, optional | Reynolds number. If omitted, it is calculated |
prandtl_ | State or float, optional | Prandtl number. If omitted, it is calculated |
correction_ | State or float, optional | Output Miropolskii correction factor |
nusselt_ | State or float, optional | Output Nusselt number |
stanton_ | State or float, optional | Output Stanton number |
Outputs
| Name | Type | Description |
|---|---|---|
convection_ | State, optional | Convective heat transfer coefficient. If omitted, a new State is created |