Skip to content

Miropolskii

fullflow.Miropolskii

Miropolskii film-boiling heat transfer coefficient for two-phase flow.

Miropolskii computes a convective heat transfer coefficient for film-boiling two-phase flow. It is useful for chilldown-style problems where vapor quality and separate liquid and vapor properties are available.

Parameters

Name Type Description
namestr

Component name

networkNetwork

Network that owns this component

mass_flowState

Fluid mass flow rate. The absolute value is used

hydraulic_diameterState or float

Hydraulic diameter of the flow passage

cross_sectional_areaState or float

Flow cross-sectional area

qualityState or float

Vapor quality

vapor_densityState

Vapor density

vapor_specific_heatState

Vapor specific heat capacity

vapor_dynamic_viscosityState

Vapor dynamic viscosity

vapor_conductivityState

Vapor thermal conductivity

liquid_densityState

Liquid density

reynolds_numberState or float, optional

Reynolds number. If omitted, it is calculated

prandtl_numberState or float, optional

Prandtl number. If omitted, it is calculated

correction_factorState or float, optional

Output Miropolskii correction factor

nusselt_numberState or float, optional

Output Nusselt number

stanton_numberState or float, optional

Output Stanton number

Outputs

Name Type Description
convection_coefficientState, optional

Convective heat transfer coefficient. If omitted, a new State is created